Amapharamitha kagesi | 5 (2.5) A 125 / 250V |
Ukulungiswa kwengcindezi | 20PA ~ 5000PA |
Ingcindezi esebenzayo | Ingcindezi eyakhayo noma engemihle |
Ukumelana Nencazelo | ≤50mΩ |
Ukucindezela Okuphezulu | I-10KPA |
Ukushisa okusebenzayo | -20℃~ 85℃ |
Usayizi wokuxhumeka | Ububanzi 6mm |
Ukumelana nokufakelwa | I-500V-DC-GETED 1MIn, ≥5MM |
Indlela yokulawula | Indlela Evulekile Nokuvalwa |
Amandla kagesi | I-500V ---- yathatha i-1min, akukho okungajwayelekile |
Indlela yokufaka | Kunconyelwe ukufakwa okuqondile |
Okusebenzayo okusebenzayo | Igesi engeyona eyingozi, amanzi, uwoyela, uketshezi |
Ileveli yokuvikela | IP65 |
Ukuhlatshwa | Ukuthengisa, ukugcina sesokhethi, isikulufa esinqenqemayo |
Shintsha umsebenzi | Imvamisa ivulekile (ivulekile eFree State), imvamisa ivaliwe (ivaliwe eFree State) |
isifanekiso | Uhla lwezingcindezi | Ingcindezi ehlukile / Inani Lokubuyisela | Ukubeka iphutha | Izesekeli Ongakukhetha |
AX03-20 | 20-200pa | I-10PA | ±I-15% | 1 imitha trachea2 Izixhumi 2 amasethi ezisekeli |
AX03-30 | 30-300pa | I-10PA | ±I-15% | |
AX03-40 | 40-400PA | 20PA | ±I-15% | |
AX03-50 | I-50-500PA | 20PA | ±I-15% | |
AX03-100 | I-100-1000PA | I-50PA | ±I-15% | I-Trachea 1.2 Meters2 Izixhumi 3 amasethi ezisekeli |
AX03-200 | 200-1000PA | 100PA | ±10% | |
AX03-500 | 500-2500PA | I-150PA | ±10% | |
AX03-1000 | I-1000-5000PA | I-200pa | ±10% |
I-Differial Pressure switch switch switch ekhethekile yokulawula ingcindezi, esekelwe umehluko wokucindezela phakathi kwezinto ezahlukahlukene, futhi idlulisela imininingwane ngokusebenzisa amasiginali kagesi ukulawula ukuvala noma ukuvulwa kwe-valve emzimbeni wokushintsha okuhlukile. Ngaphansi kwesenzo sengcindezi, amafutha angena emgodini ohlukile wePress Pressure switch Piston kusuka ku-Piperines Main Breat b, bese ucindezela ukushintshwa kwe-Pipelines ku-Systen Elead Board uku-oda i-valve yokulawula ukushintsha ukuqondiswa.Esikhathi kulokhu, ipayipi eliyinhloko A licindezelwe, futhi b selilayishiwe. I-piston igxile ngaphansi kwesenzo sentwasahlobo emgodini wokugcina ezimbili, oxhumana nabo be-stroke switch 1 no-2 banqanyuliwe, futhi ibhuloho lokuxhumana lisesimweni sokungathathi hlangothi.
Uhlelo luqala umjikelezo wesibili. Lapho umehluko wengcindezi phakathi kwepayipi eliyinhloko a no-B ufinyelela inani elisethiwe futhi, ipiston liya kwesokudla, i-stroke switch oxhumana nabo, bese kuthi isibonakaliso se-stroke sibangela ukuthi i-valve evuselelekile, Qala umjikelezo olandelayo womsebenzi.
Ukushintshwa kwengcindezi okuhlukile kungasetshenziswa kabanzi kuma-chiller amakhulu, aphakathi nendawo amancane apholile noma apholile asebenzisa ukushintshana kokushisa kwamanzi, ukulinganisa okugcwele amanzi, futhi kusetshenziswa kakhulu ekuthwebuleni komoya, uketshezi kanye nezinga le-Filter ukulawula.
Ukusetshenziswa kokushintshwa kwengcindezi yokwehlukanisa ohlelweni lwe-HVAC kulawulwa ikakhulukazi ngokumelana nokugeleza kwejika le-HVAC (i-tube-in-tube, uhlobo lokushisa olusetshenziswayo, izihlungi zamanzi, ama-valves kanye namaphampu anokucindezela kokucindezela kanye nokugeleza kokucindezela amajika. Uma nje umehluko wengcindezi olinganisekayo ezinhlangothini zombili ze-Pressure Press switch uqhathaniswa nenani elisethiwe, ukugeleza kungalawulwa ngokunembile.
11